Steel fire protection coatings at a glance
Steel fire protection coatings – Introduction
The design with steel is an essential element of modern architecture. Due to its high load-bearing capacity, this versatile building material enables far-reaching, exciting constructions that can be optimally integrated into building concepts and accentuate them in a targeted manner.
Safety aspects must always be taken into account during construction, which sometimes seem to contradict filigree architecture. Fire protection coating systems are perfectly suited to counteract this contradiction: With their corrosion and fire protection, they meet technical requirements and can simultaneously emphasize the aesthetic appearance of a steel construction.
Fire resistant coatings have been successfully used in the construction industry for over fifty years to minimize the negative effects of fire. The commitment of manufacturers and their achievements in the field of research and development as well as the optimization of application methods have contributed significantly over the past decades to the fact that the former “orange-peel” image of coatings is now almost forgotten. Thanks to the corresponding expertise of the manufacturers, good raw materials and experienced applicators, the highest quality surfaces can be achieved today.
You are currently viewing a placeholder content from YouTube. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationTITLE: Intumescent Fire Protection Coatings
CHANNEL: IGSB
PUBLISHED: 21 October 2024
ORIGINAL LANGUAGE: English
TOPIC: Fire protection of steel structures using intumescent (swelling) coatings
SHORT DESCRIPTION:
The video explains why structural fire protection matters, how intumescent coatings are built up, how they react when exposed to fire, and what benefits they offer architects, building owners and building occupants.
CONTENT BY SECTION:
1. Why fire protection matters
– Fires cause daily deaths and serious injuries across Europe.
– Economic losses in Europe: approx. EUR 30 billion per year.
– Total global cost of fires: estimated at around 1% of GDP.
– Germany: approx. 200 major fires per year with losses above EUR 500,000; fire service costs approx. EUR 4 billion annually.
2. Risk in steel buildings
– Steel loses its load-bearing capacity from about 500 °C.
– Particularly at risk: large public buildings such as airports, railway stations, exhibition halls and shopping centres (many people in unfamiliar surroundings).
– Modern large buildings are often open steel-and-glass structures.
3. Protective effect
– Intumescent coatings act as thermal insulation for the steel.
– They maintain structural stability for 60 to 120 minutes.
– Purpose: safe evacuation and time for fire and rescue services.
4. Coating system (demonstrated on an H-beam)
– Primer
– Intumescent layer, usually spray-applied
– Top coat for colour and protection against mechanical stress and moisture
5. Reaction mechanism in a fire
– Binder softens
– Acid components are released
– Carbon source (e.g. a polyalcohol) chars
– Blowing agent produces gas
– Mixture foams and expands
– Cross-linking forms a stable, inorganic insulating char
6. Comparison and testing
– Graph: unprotected steel reaches critical temperature quickly; coated steel only after up to 120 minutes.
– Fire test: approx. 30 cm H-beam in a gas-fired furnace following a standard temperature curve. Foam forms within minutes, is fully developed after about 15 minutes and turns white.
– Additional demonstration on wood: gas bubbles, then blackening through charring, finally a white foam layer.
7. Benefits
– Design freedom; steel remains visible and aesthetically appealing
– Cost-effective way to meet current safety requirements
– Maintenance-free, unlike active systems such as sprinklers
– Can be applied off-site in the factory, often more economical than on-site application
KEYWORDS:
fire protection, intumescent coating, intumescent paint, structural steel, fire resistance, R30/R60/R90/R120, passive fire protection, steel beam, fire test, standard fire curve, char formation